[2019-07-27 02:02:34.251] APC: (the area power controller) at Shared Engineering Storage (156, 133, 2) with dir (8 | WEST) has pixel_x value (-26 - should be -25.) [2019-07-27 02:02:34.268] APC: (the area power controller) at Engineering Foyer (160, 136, 2) with dir (2 | SOUTH) has pixel_y value (-26 - should be -23.) [2019-07-27 02:02:34.690] APC: (Labor Camp Security APC) at Labor Camp Security (24, 36, 5) with dir (4 | EAST) has pixel_x value (0 - should be 24.) [2019-07-27 02:02:36.875] APC: (Worn-out APC) at Derelict Medbay (88, 132, 6) with dir (2 | SOUTH) has pixel_y value (-24 - should be -23.) [2019-07-27 02:02:36.897] APC: (Worn-out APC) at Derelict Primary Hallway (101, 125, 6) with dir (2 | SOUTH) has pixel_y value (-24 - should be -23.) [2019-07-27 02:02:36.945] APC: (Worn-out APC) at Derelict Control Room Access (128, 146, 6) with dir (2 | SOUTH) has pixel_y value (-24 - should be -23.) [2019-07-27 02:02:36.949] APC: (Worn-out APC) at Derelict Control Room Access (131, 165, 6) with dir (2 | SOUTH) has pixel_y value (-24 - should be -23.) [2019-07-27 02:02:36.956] APC: (Worn-out APC) at Derelict Control Room (135, 154, 6) with dir (2 | SOUTH) has pixel_y value (-24 - should be -23.) [2019-07-27 02:02:36.967] APC: (Worn-out APC) at Derelict Arrival Centre (142, 129, 6) with dir (2 | SOUTH) has pixel_y value (-24 - should be -23.) [2019-07-27 02:02:37.074] APC: (Worn-out APC) at Old Teleporter (96, 200, 10) with dir (2 | SOUTH) has pixel_y value (-24 - should be -23.) [2019-07-27 02:02:37.434] APC: (Worn-out APC) at Ruskie DJ Station (47, 125, 9) with dir (2 | SOUTH) has pixel_y value (-24 - should be -23.) [2019-07-27 02:02:38.524] APC: (Worn-out APC) at Turreted Outpost (208, 129, 9) with dir (2 | SOUTH) has pixel_y value (-24 - should be -23.) [2019-07-27 02:03:05.271] There are 3 active turfs at roundstart caused by a difference of the air between the adjacent turfs. You can see its coordinates using "Mapping -> Show roundstart AT list" verb (debug verbs required). [2019-07-27 02:03:21.536] APC: (Salvage Ship Engineering APC) at Abandoned Ship Engine (140, 10, 12) with dir (2 | SOUTH) has pixel_y value (-24 - should be -23.) [2019-07-27 02:03:21.704] APC: (Salvage Ship Crew Quarters APC) at Abandoned Ship Crew Quarters (158, 20, 12) with dir (2 | SOUTH) has pixel_y value (-24 - should be -23.) [2019-07-27 02:03:22.028] The external airlock at Abandoned Ship Engine (142, 11, 12) failed to find a valid airlock to cyclelink with! [2019-07-27 02:03:22.028] The external airlock at Abandoned Ship Bar (150, 11, 12) failed to find a valid airlock to cyclelink with! [2019-07-27 02:03:22.028] The external airlock at Abandoned Ship Engine (142, 21, 12) failed to find a valid airlock to cyclelink with! [2019-07-27 02:03:22.028] The external airlock at Abandoned Ship Crew Quarters (150, 21, 12) failed to find a valid airlock to cyclelink with!